TO MAKE THE WORLD CLOSER TO THE TRUTH
Availability: | |
---|---|
Quantity: | |
TDL-6MC
TOP
It is suitable for limited workspace such as blood collection vehicles, blood donation houses, and medical biochemistry laboratories.
Feature:
1. Power coated housing. Stainless steel chamber with guarding ring.
2. Compact design saves your working desk space.
3. Reliable drive system. Variable frequency motor maintenance free.
4. Electronic safety lock prevent cover opening during centrifugation.
5. Manually lid open in case of failure or emergency.
6. Pneumatic spring supports prevent falling of lid.
7. Pre-cooling during standstill. CFC free refrigeration system.
8. Recall of last settings. Parameters can be changed during operation.
9. Microprocessor control of all functions: speed, time, temperature, acceleration/deceleration, RCF, error display.
10. The self-diagnostic system provides protection for imbalance, over-temperature / speed/voltage, and electronic lock.
11. Produced according to national and international safety standards (ISO9001, ISO13485, ISO14001, EN IEC 61010, EN IEC 61326).
12. * Optional: Automatic lid opening at the end of run.
13. * Optional: Short spin.
14. * Optional: Rotor identification.
It is suitable for limited workspace such as blood collection vehicles, blood donation houses, and medical biochemistry laboratories.
Feature:
1. Power coated housing. Stainless steel chamber with guarding ring.
2. Compact design saves your working desk space.
3. Reliable drive system. Variable frequency motor maintenance free.
4. Electronic safety lock prevent cover opening during centrifugation.
5. Manually lid open in case of failure or emergency.
6. Pneumatic spring supports prevent falling of lid.
7. Pre-cooling during standstill. CFC free refrigeration system.
8. Recall of last settings. Parameters can be changed during operation.
9. Microprocessor control of all functions: speed, time, temperature, acceleration/deceleration, RCF, error display.
10. The self-diagnostic system provides protection for imbalance, over-temperature / speed/voltage, and electronic lock.
11. Produced according to national and international safety standards (ISO9001, ISO13485, ISO14001, EN IEC 61010, EN IEC 61326).
12. * Optional: Automatic lid opening at the end of run.
13. * Optional: Short spin.
14. * Optional: Rotor identification.
Technical data:
Model | TDL-6MC |
Max. RPM/RCF for angle rotor | 4200rpm / 2197×g |
Max. Capacity for angle rotor | 12×10ml |
Speed Increment | 1rpm |
Speed Accuracy | ±20rpm |
Temp. Range | -20℃~+40℃ |
Temp Accuracy | ±2℃ |
Timer Range | 0~99min59s |
Acc / Dec rates | 10/10 |
Power Supply | AC220V / 50~60Hz |
Power Requirement | 368W |
Noise | <55db |
Screen | LCD screen |
Machine Body | Plastic and metal frame |
Net Weight (without rotor) | 32kg |
Machine Dimension(L×W×H) | 340×590×310mm (L×W×H) |
Rotor List
Angle Rotor | AL1215-2 | |
Max.Capacity | 12×10ml | |
Max. Speed | 4200rpm | |
Max. RCF | 2197×g | |
Angle | 55° | |
ØxL(mm) | B11239 18×88mm | |
Adaptor | A20121 | 12×5ml (vacuum tube) |
A20122 | 12×2ml (vacuum tube) |
Technical data:
Model | TDL-6MC |
Max. RPM/RCF for angle rotor | 4200rpm / 2197×g |
Max. Capacity for angle rotor | 12×10ml |
Speed Increment | 1rpm |
Speed Accuracy | ±20rpm |
Temp. Range | -20℃~+40℃ |
Temp Accuracy | ±2℃ |
Timer Range | 0~99min59s |
Acc / Dec rates | 10/10 |
Power Supply | AC220V / 50~60Hz |
Power Requirement | 368W |
Noise | <55db |
Screen | LCD screen |
Machine Body | Plastic and metal frame |
Net Weight (without rotor) | 32kg |
Machine Dimension(L×W×H) | 340×590×310mm (L×W×H) |
Rotor List
Angle Rotor | AL1215-2 | |
Max.Capacity | 12×10ml | |
Max. Speed | 4200rpm | |
Max. RCF | 2197×g | |
Angle | 55° | |
ØxL(mm) | B11239 18×88mm | |
Adaptor | A20121 | 12×5ml (vacuum tube) |
A20122 | 12×2ml (vacuum tube) |