Class II Type B2 Biosafety Cabinets
You are here: home » Products » Biological Safety Cabinets » Class II Type B2 Biosafety Cabinets

Product Category

Class II Type B2 Biosafety Cabinets


Class II Type B2 Biosafety Cabinets are high-performance containment systems designed for laboratories handling hazardous chemical vapors or toxic volatile substances along with biological materials. Unlike Type A2 models, Type B2 cabinets feature 100% total exhaust of filtered air without recirculation, making them the preferred choice for applications involving carcinogens, radionuclides, or chemical fixatives.


These cabinets provide triple protection—for personnel, products, and the environment—by combining vertical laminar flow, front airflow barrier, and external ducting. They are widely used in microbiology, molecular biology, pharmaceutical compounding, toxicology labs, and hospital settings.


Key features include:

  • 100% HEPA-filtered exhaust with no recirculated air

  • Built-in duct connection to external exhaust systems

  • Suitable for hazardous vapors and chemical-laden procedures

  • Independent airflow monitoring and automatic safety alerts

  • Stainless steel work zone and chemical-resistant construction


Class II Type B2 BSCs comply with international biosafety standards such as NSF/ANSI 49 and EN 12469, ensuring maximum containment and laboratory safety. They are ideal for critical research and clinical environments where operator safety and air quality are non-negotiable.


Choose Class II Type B2 Biosafety Cabinets for reliable protection when working with both biological agents and chemical hazards.


  • Class II A2 Biological Safety Cabinet, T-1300IIA/B2
     
    · Exhaust mode: 30% Air Exhaust,70% Air Recirculation
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material (Economy type) :Steel and wood structure
    · Work area size (W1*D1*H1) : 1000*700*620mm
    · Dimensions (W*D*H) : 1200*740*1950mm
     
    Model: T-1300IIA/B2
    Add to Basket
  • Class II B2 Biological Safety Cabinet, T-1300IIA/B3
     
    · Exhaust mode:100% outside
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material:Steel and wood structure
    · Work area size (W1*D1*H1) :1340*650*600mm
    · Dimensions (W*D*H) :1540*785*1950mm
     
    Model: T-1300IIA/B3
    Add to Basket
  • Class II B2 Biological Safety Cabinet, T-1000IIB2
     
    · Exhaust mode:100% outside
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material:Steel and wood structure
    · Work area size (W1*D1*H1) :1000*650*580mm
    · Dimensions (W*D*H) :1195*750*1950mm
     
    Model: T-1000IIB2
    Add to Basket
  • Class II B2 Biological Safety Cabinet, T-1300IIB2
     
    · Exhaust mode:100% outside
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material:Steel and wood structure
    · Work area size (W1*D1*H1) :1300*650*580mm
    · Dimensions (W*D*H) :1500*785*1950mm
     
    Model: T-1300IIB2
    Add to Basket
  • Class II B2 Biological Safety Cabinet, T-1600IIB
     
    · Exhaust mode:100% outside
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material:Steel and wood structure
    · Work area size (W1*D1*H1) :1600*650*580mm
    · Dimensions (W*D*H) :1800*785*1950mm
     
    Model: T-1600IIB2
    Add to Basket
  • Class II B2 Biosafety Cabinet, TS-1000IIB2
     
    · Exhaust mode:100% outside
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material:All steel structure
    · Work area size (W1*D1*H1) :1040*650*620mm
    · Dimensions (W*D*H) :1200*800*2270mm
     
    Model: TS-1000IIB2
    Add to Basket
  • Class II B2 Biosafety Cabinet, TS-1300IIB2
     
    · Exhaust mode:100% outside
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material:All steel structure
    · Work area size (W1*D1*H1) :1340*650*620mm
    · Dimensions (W*D*H) :1500*800*2270mm
     
    Model: TS-1300IIB2
    Add to Basket
  • Class II B2 Biosafety Cabinet, TS-1600IIB2
     
    · Exhaust mode:100% outside
    · Cleanliness:Class 100@≥0.5μm (US Federal 209E)
    · Number of colonies:≤0.5/dish per hour (Φ90㎜ Petri dish)
    · Material:All steel structure
    · Work area size (W1*D1*H1) :1640*650*620mm
    · Dimensions (W*D*H) :1800*800*2270mm
     
    Model: TS-1600IIB2
    Add to Basket
To Make The World Closer To The Truth
ZHEJIANG TOP INSTRUMENT CO.,LTD., as a subsidiary of TOP Cloud agri, is a high-tech enterprise specializing in the R&D, manufacturing, sales for laboratory equipments, and provision of comprehensive laboratory solutions.

CONTACT US

  +86-571-86062776
 +86-571-86059660
   11-12th Floor, 3rd Building, Xiangyuan Rd. China (Hangzhou) Wisdom Information Industry Park, Hangzhou, P.R.C 310015
Copyright   2023 Zhejiang Top Instrument Co., Ltd. Support by Leadong. Sitemap.Privacy Policy