Availability: | |
---|---|
Quantity: | |
TZ-4MT
TOP
It is computer-controlled and can achieve automated centrifugation, completely replacing manual operation and reducing the risk of sample infection during the centrifugation process.
Feature:
1. Manually lid open in case of failure or emergency.
2. Compressor refrigeration, precise temperature control.
3. Pre-cooling during standstill. CFC free refrigeration system.
4. Microprocessor control of all functions: speed, time, temperature, acceleration/deceleration, RCF, program memory, error display.
5. Touch LCD screen without buttons.
6. The self-diagnostic system provides protection for imbalance, over-temperature / speed/voltage, and electronic lock.
7. Equipped with RS485 interface, capable of connecting to terminal.
8. Customizable sample window and machine height, flexible adaptation.
9. Produced according to national and international safety standard (ISO9001, ISO13485, ISO14001, EN IEC 61010, EN IEC 61326).
It is computer-controlled and can achieve automated centrifugation, completely replacing manual operation and reducing the risk of sample infection during the centrifugation process.
Feature:
1. Manually lid open in case of failure or emergency.
2. Compressor refrigeration, precise temperature control.
3. Pre-cooling during standstill. CFC free refrigeration system.
4. Microprocessor control of all functions: speed, time, temperature, acceleration/deceleration, RCF, program memory, error display.
5. Touch LCD screen without buttons.
6. The self-diagnostic system provides protection for imbalance, over-temperature / speed/voltage, and electronic lock.
7. Equipped with RS485 interface, capable of connecting to terminal.
8. Customizable sample window and machine height, flexible adaptation.
9. Produced according to national and international safety standard (ISO9001, ISO13485, ISO14001, EN IEC 61010, EN IEC 61326).
Technical data:
Model | TZ-4MT |
Max. RPM/RCF | 4200rpm / 3582×g |
Max. Capacity | 4×30×5/2ml |
Test tube size | Customizable |
Speed accuracy | ±20 rpm |
Temp. range | -20℃~+40℃ |
Pre-cooling time from 25℃ to 4℃ | ≤8min |
Temp accuracy | ±2℃ |
Timer range | Controlled by terminal |
Fastest Acc / Dec time | 1min45s / 2min46s |
Rotor positioning | Equipped with a four part stop function for positioning, the center position of the adapter can be repeatedly positioned by ≤±1mm |
Angle repeatability positioning accuracy | ±0.2° |
Window size | 130×100mm (Customizable) |
Maximum amount of unbalance | <15g |
Maximum unbalance tolerance | 40g |
Communication Interface | RS485, ModbusRTU |
Control mode | Communicate with the terminal through a network or serial port |
Distance from the bottom of the adapter to the top of the door cover | 201.5±2.5mm |
Power supply | AC220V 50/60Hz |
Power requirement | 3KW |
Noise | <68db |
Display | Digital display |
Motor | Converter Motor, direct drive |
Machine Dimension(L×W×H) | 550×622×790 / 742.5mm |
Rotor List
Swing Rotor | SA1205 | |
Cat. No. | B20443 | |
Max.Capacity | 120×5/2ml | |
Max. Speed | 4200rpm | |
Max. RCF | 3582×g | |
ØxL(mm) | 128×55mm | |
Adaptor | A13030 | 4×30×5/2ml (vacuum tube) |
A12631 | 4×26×5/2ml (vacuum tube) |
Technical data:
Model | TZ-4MT |
Max. RPM/RCF | 4200rpm / 3582×g |
Max. Capacity | 4×30×5/2ml |
Test tube size | Customizable |
Speed accuracy | ±20 rpm |
Temp. range | -20℃~+40℃ |
Pre-cooling time from 25℃ to 4℃ | ≤8min |
Temp accuracy | ±2℃ |
Timer range | Controlled by terminal |
Fastest Acc / Dec time | 1min45s / 2min46s |
Rotor positioning | Equipped with a four part stop function for positioning, the center position of the adapter can be repeatedly positioned by ≤±1mm |
Angle repeatability positioning accuracy | ±0.2° |
Window size | 130×100mm (Customizable) |
Maximum amount of unbalance | <15g |
Maximum unbalance tolerance | 40g |
Communication Interface | RS485, ModbusRTU |
Control mode | Communicate with the terminal through a network or serial port |
Distance from the bottom of the adapter to the top of the door cover | 201.5±2.5mm |
Power supply | AC220V 50/60Hz |
Power requirement | 3KW |
Noise | <68db |
Display | Digital display |
Motor | Converter Motor, direct drive |
Machine Dimension(L×W×H) | 550×622×790 / 742.5mm |
Rotor List
Swing Rotor | SA1205 | |
Cat. No. | B20443 | |
Max.Capacity | 120×5/2ml | |
Max. Speed | 4200rpm | |
Max. RCF | 3582×g | |
ØxL(mm) | 128×55mm | |
Adaptor | A13030 | 4×30×5/2ml (vacuum tube) |
A12631 | 4×26×5/2ml (vacuum tube) |