Availability: | |
---|---|
Quantity: | |
TZ10
TOP
It is used for standard physiochemical tests on the relative density and fat volume of milk products with the method of Gerber. It applies in such fields as milk and milk products, medicine and pharmacy, biochemistry, and hygienic food to measure the volume or percentage of the fat centrifuged from milk.
Feature:
1. Power coated housing. Stainless steel chamber with guarding ring.
2. Reliable drive system. Variable frequency motor maintenance free.
3. Electronic safety lock prevent cover opening during centrifugation.
4. Manually lid open in case of failure or emergency.
5. Pneumatic spring supports prevent falling of lid.
6. Recall of last settings. Parameters can be changed during operation.
7. Microprocessor control of all functions: speed, time, temperature, acceleration/deceleration, RCF, *program memory, error display.
8. The self-diagnostic system provides protection for imbalance, over-temperature / speed/voltage, and electronic lock.
9. Produced according to national and international safety standard
10. Optional: Automatic lid opening at the end of run.
It is used for standard physiochemical tests on the relative density and fat volume of milk products with the method of Gerber. It applies in such fields as milk and milk products, medicine and pharmacy, biochemistry, and hygienic food to measure the volume or percentage of the fat centrifuged from milk.
Feature:
1. Power coated housing. Stainless steel chamber with guarding ring.
2. Reliable drive system. Variable frequency motor maintenance free.
3. Electronic safety lock prevent cover opening during centrifugation.
4. Manually lid open in case of failure or emergency.
5. Pneumatic spring supports prevent falling of lid.
6. Recall of last settings. Parameters can be changed during operation.
7. Microprocessor control of all functions: speed, time, temperature, acceleration/deceleration, RCF, *program memory, error display.
8. The self-diagnostic system provides protection for imbalance, over-temperature / speed/voltage, and electronic lock.
9. Produced according to national and international safety standard
10. Optional: Automatic lid opening at the end of run.
Technical data
Model | TZ10 |
Max. RPM/RCF | 4000rpm / 3011×g |
Max. Capacity | 8 samples |
Speed increment | 50rpm |
Speed accuracy | ±20rpm |
Temperature range | RT ~ 70℃ |
Timer range | 0min~99min59s |
Acc / Dec rates | 10/10 |
Power supply | AC220V / 50~60Hz |
Power requirement | 750W |
Noise | <55db |
Screen | LCD Screen |
Machine body | Metal frame |
Net weight (without rotor) | 65kg |
Machine dimension(L×W×H) | 540×650×480mm |
Rotor List
Swing Rotor | AARZ8 |
Max.Capacity | 8 samples |
Max. Speed | 4000rpm |
Max. RCF | 3011×g |
Technical data
Model | TZ10 |
Max. RPM/RCF | 4000rpm / 3011×g |
Max. Capacity | 8 samples |
Speed increment | 50rpm |
Speed accuracy | ±20rpm |
Temperature range | RT ~ 70℃ |
Timer range | 0min~99min59s |
Acc / Dec rates | 10/10 |
Power supply | AC220V / 50~60Hz |
Power requirement | 750W |
Noise | <55db |
Screen | LCD Screen |
Machine body | Metal frame |
Net weight (without rotor) | 65kg |
Machine dimension(L×W×H) | 540×650×480mm |
Rotor List
Swing Rotor | AARZ8 |
Max.Capacity | 8 samples |
Max. Speed | 4000rpm |
Max. RCF | 3011×g |