TD4-1
TOP
It is widely used for biochemical tests such as blood cell washing, blood type identification, and cross matching. Special rotors are used for both red blood cell washing and white blood cell washing to ensure the stability and reliability of results.
Feature:
1. Power coated housing. Stainless steel chamber with guarding ring.
2. Microprocessor control, digital display, directly driven by a brushless motor, programmed timer.
3. Within 3 minutes, time will be set, increased, displayed, and controlled to meet the standard requirements.
4. Automatic balance, low noise.
5. Produced according to national and international safety standard (ISO9001, ISO13485, ISO14001, EN IEC 61010, EN IEC 61326).
It is widely used for biochemical tests such as blood cell washing, blood type identification, and cross matching. Special rotors are used for both red blood cell washing and white blood cell washing to ensure the stability and reliability of results.
Feature:
1. Power coated housing. Stainless steel chamber with guarding ring.
2. Microprocessor control, digital display, directly driven by a brushless motor, programmed timer.
3. Within 3 minutes, time will be set, increased, displayed, and controlled to meet the standard requirements.
4. Automatic balance, low noise.
5. Produced according to national and international safety standard (ISO9001, ISO13485, ISO14001, EN IEC 61010, EN IEC 61326).
Technical data
Model | TD4-1 |
Max. RPM/RCF for swing rotor | 4500rpm / 2000×g |
Max. Capacity for swing rotor | 12×5ml |
Timer Range | Program control |
Power Supply | AC220V / 50~60Hz |
Power Requirement | 60W |
Noise | <55db |
Screen | Digital Screen |
Net Weight (without rotor) | 19kg |
Machine Dimension(L×W×H) | 350×440×260mm |
Rotor List
HLA Rotor | Max speed : 4500rpm Capacity : 12 x 2ml Max rcf : 2000xg | 180s to separate lymphocytes and cultured cells |
Max speed : 3200rpm Capacity : 12 x 1.5ml Max rcf : 1000xg | 3s to get rid of platelet | |
Max speed : 3200rpm Capacity : 12 x 0.5ml Max rcf : 1000xg | 60s to wash lymphocyte | |
SERO Rotor | Max speed : 2100rpm Capacity : 12 x 5ml Max rcf : 500xg | 60s to judge blood type, observe the response of hemagglutination reaction |
Max speed : 3000rpm Capacity : 12 x 5ml Max rcf : 1000xg | 15s for experiments of Cross-adaptation and anti-ball element | |
Max speed : 3000rpm Capacity : 12 x 5ml Max rcf : 1000xg | 60s to wash blood cell, extract serum and plasma | |
Remark:5ml: Ø13x100mm(L) 2ml: Ø13x75mm(L) |
Technical data
Model | TD4-1 |
Max. RPM/RCF for swing rotor | 4500rpm / 2000×g |
Max. Capacity for swing rotor | 12×5ml |
Timer Range | Program control |
Power Supply | AC220V / 50~60Hz |
Power Requirement | 60W |
Noise | <55db |
Screen | Digital Screen |
Net Weight (without rotor) | 19kg |
Machine Dimension(L×W×H) | 350×440×260mm |
Rotor List
HLA Rotor | Max speed : 4500rpm Capacity : 12 x 2ml Max rcf : 2000xg | 180s to separate lymphocytes and cultured cells |
Max speed : 3200rpm Capacity : 12 x 1.5ml Max rcf : 1000xg | 3s to get rid of platelet | |
Max speed : 3200rpm Capacity : 12 x 0.5ml Max rcf : 1000xg | 60s to wash lymphocyte | |
SERO Rotor | Max speed : 2100rpm Capacity : 12 x 5ml Max rcf : 500xg | 60s to judge blood type, observe the response of hemagglutination reaction |
Max speed : 3000rpm Capacity : 12 x 5ml Max rcf : 1000xg | 15s for experiments of Cross-adaptation and anti-ball element | |
Max speed : 3000rpm Capacity : 12 x 5ml Max rcf : 1000xg | 60s to wash blood cell, extract serum and plasma | |
Remark:5ml: Ø13x100mm(L) 2ml: Ø13x75mm(L) |