  • Portable Ozone Meter for Water | DPD Photometric Method Ozone Tester, Handheld Water Quality Analyzer
    Measuring Range: 0.05–2.50 mg/L (ozone in water)
    Accuracy: ≤±0.05 mg/L (<1.0 mg/L); ≤±5% (≥1.0 mg/L)
    Principle: DPD photometric method, 520 nm LED light source
    Battery Life: >24 hours continuous use
    Protection: IP65 waterproof, portable lightweight design
    Dimension & Weight: 128×70×48 mm, 188 g (with battery)
    Operating Environment: 0–40°C, ≤90% RH (non-condensing)
     
    Model: PT-D01F
    Add to Basket
  • PT-C03F Portable Chlorine Dioxide Meter | DPD Photometric Water Quality Analyzer for Drinking, Swimming & Industrial Water
    Measurement Range: 0.1–5.00 mg/L chlorine dioxide
    Accuracy: ≤ ±0.05 mg/L (<1 mg/L), ≤ ±5% (≥1 mg/L)
    Wavelength: 520 nm, LED light source
    Operation: Intuitive display, simple operation, fast analysis with low reagent use
    Portability: Compact (128×70×48 mm), lightweight (188 g), IP65 protection
    Battery Life: Over 24 hours continuous use
    Principle: DPD photometric method, chlorine dioxide reacts with DPD to produce a red-colored solution
     
    Model: PT-C03F
    Add to Basket
  • Portable Residual Chlorine Meter PT-C01F | DPD Photometric Water Quality Analyzer for Drinking, Swimming & Aquaculture Water
    Measurement Range: 0.05–3.00 mg/L residual chlorine
    Precision: ≤ ±0.05 mg/L (<1 mg/L), ≤ ±5% (≥1 mg/L)
    Wavelength: 520 nm, LED light source
    Operation: Intuitive display, simple operation, fast analysis with low reagent use
    Portability: Compact (128×70×48 mm), lightweight (188 g), IP65 protection
    Battery Life: Over 24 hours continuous use
    Principle: DPD spectrophotometric method
     
    Model: PT-C01F
    Add to Basket
  • Benchtop Water Quality Meter PL Series – Accurate DPD Photometric Detection for Residual Chlorine, CO₂, and Ozone
    Function: Benchtop water quality meter using DPD photometric method and photoelectric colorimetry for accurate water ion analysis
    Determination Parameters: Residual chlorine, total chlorine, combined residual chlorine, carbon dioxide, ozone
    Measuring Range & Accuracy: 0–5 mg/L (PL-1), 0–10 mg/L (PL-2), 0–2 mg/L (PL-3), minimum indication 0.01 mg/L, linear error ±5% FS, repeatability 3%
    Display & Operation: Touch buttons, LCD with backlight, low voltage indication, automatic shutdown after 10 minutes of inactivity
    Calibration & Light Source: Automatic zeroing and calibration, high-intensity long-life light source, 30-second warm-up, maintenance-free
    Power & Design: AC 220V ±10%, 50Hz, 3W, desktop design, stable and reliable for long-term use
     
    Model: PL Series
    Add to Basket
  • P93706A Portable Colorimetric Chlorine Analyzer – Accurate Low-Range 0–30 mg/L Water Testing
    Function: Portable colorimetric chlorine analyzer for measuring available chlorine in water using photoelectric colorimetry
    Measuring Range & Accuracy: 0–30 mg/L, minimum indication 0.01 mg/L, linear error ±5% FS
    Display & Operation: Microcomputer touch keyboard, direct reading concentration value, automatic zeroing and calibration, average calculation, timer reminder
    Power & Portability: Battery-powered (9V carbon or alkaline), low power consumption, automatic shutdown after 10 minutes of inactivity, lightweight 170g
    Storage & Connectivity: Automatic data storage with power-off protection, optional USB or RS232 data output, optional AC/DC power adapter
    Measuring Cell & Conditions: Φ25 mm colorimetric bottle, automatic wavelength selection, operating temperature 0–50°C, relative humidity 0–90%, dimensions 162×60×33 mm
     
    Model: P93706A
    Add to Basket
  • P93706B High-Range Portable Colorimetric Chlorine Analyzer – Accurate 0–250 mg/L Water Testing
    Function: Portable high-range colorimetric chlorine analyzer for measuring available chlorine in water using photoelectric colorimetry
    Measuring Range & Accuracy: 0–250 mg/L, minimum indication 0.1 mg/L, linear error ±5% FS
    Display & Operation: Microcomputer touch keyboard, direct reading concentration value, automatic zeroing and calibration, average calculation, timer reminder, slope calibration
    Power & Portability: Battery-powered (9V carbon or alkaline), low power consumption, automatic shutdown after 10 minutes of inactivity, lightweight 170g
    Storage & Connectivity: Automatic data storage with power-off protection, optional USB or RS232 data output, optional AC/DC power adapter
    Measuring Cell & Conditions: Φ25 mm colorimetric bottle, automatic wavelength selection, operating temperature 0–50°C, relative humidity 0–90%, dimensions 162×60×33 mm
     
    Model: P93706B
    Add to Basket
  • Portable Multi-Parameter Water Quality Meter – Chlorine, CO₂, Ozone Testing with DPD Photometric Method
    Function: Portable multi-parameter water quality meter using DPD photometric method with photoelectric colorimetry
    Measurement Parameters: Residual chlorine, total chlorine, combined residual chlorine, carbon dioxide, ozone
    Measuring Range & Accuracy: 0–5 mg/L, 0–10 mg/L, 0–2 mg/L; minimum indication 0.01 mg/L; linear error ±5% FS; repeatability 3%
    Display & Operation: Microcomputer touch buttons, LCD backlit display, auto-zero and calibration, stable and maintenance-free performance
    Power Supply: 6F22 9V battery, with low voltage prompt and auto shutdown after 10 minutes
    Portability: Compact design with portable case, fast warm-up (30 seconds), equipped with rapid determination reagents
     
    Model: PL-1B、2B、3B
    Add to Basket
  • Multi-Parameter Water Quality Analyzer P9024 Controller | DPD Photometric Method for Chlorine, Ozone, CO₂ Testing
    Test Method: DPD photoelectric colorimetric determination
    Parameters: Ozone, Chlorine, Total Chlorine, Carbon Dioxide
    Measuring Range: 0–5 mg/L (Ozone 0–2 mg/L)
    Minimum Indication: 0.01 mg/L; Linearity Error: ±5% F.S; Repeatability: 3%
    Features: Dual optical path system, automatic light source selection, desktop microcomputer configuration
    Power Supply: DC 9V / 0.1A
    Optional: Built-in printer, rapid assay reagents for long-term stable supply
     
    Model: P9024
    Add to Basket
  • Portable Turbidity and Suspended Solids Meter with Dual 90° & 180° Detectors – ISO7027 Compliant Water Quality Tester
    Measurement Range: 0–1000 NTU (Turbidity), 0–1000 mg/L (Suspended Solids)
    Resolution: 0.01 / 0.1 / 1.0 NTU or mg/L
    Measurement Accuracy: ≤ ±0.1 NTU (≤ 1 NTU), ≤ ±5% (> 4 NTU)
    Repeatability: ≤ ±0.1 NTU (< 10 NTU), ≤ ±1% (> 10 NTU)
    Operating Temperature: 5–40°C
    Protection Rating: IP65 Waterproof and Dustproof
    Weight / Dimensions: 290g, 170 × 72 × 44 mm
     
    Model: PT-XZ03
    Add to Basket
  • Portable Turbidity Meter with Dual-Channel NIR Light Source | ISO7027 Compliant Turbidimeter
    Measurement Range: 0~1000 NTU (three selectable ranges: 0-20, 0-200, 0-1000 NTU)
    Resolution: 0.01 / 0.1 / 1.0 NTU
    Accuracy: ≤±0.1 NTU for <1 NTU/hour drift; ≤±0.2 NTU for 1-4 NTU/hour drift; ≤±5% for >4 NTU/hour drift
    Repeatability: ≤±0.1 NTU (<10 NTU/hour), ≤±1% (≥10 NTU/hour)
    Zero Drift: ≤±0.3% FS/30 minutes
    Operating Temperature: 5~40°C
    Protection Level: IP65, Lithium or Dry Battery Power Supply
     
    Model: PY-BZ08
    Add to Basket
To Make The World Closer To The Truth
ZHEJIANG TOP INSTRUMENT CO.,LTD., as a subsidiary of TOP Cloud agri, is a high-tech enterprise specializing in the R&D, manufacturing, sales for laboratory equipments, and provision of comprehensive laboratory solutions.

CONTACT US

  +86-571-86062776
 +86-571-86059660
   11-12th Floor, 3rd Building, Xiangyuan Rd. China (Hangzhou) Wisdom Information Industry Park, Hangzhou, P.R.C 310015
Copyright   2023 Zhejiang Top Instrument Co., Ltd. Support by Leadong. Sitemap.Privacy Policy