TO MAKE THE WORLD CLOSER TO THE TRUTH
Availability: | |
---|---|
Quantity: | |
PY-260
TOP
Portable turbidimeter combines the scattered light method and transmitted light method, the instrument is set up with 90 ° and 180 ° two detectors, 180 ° detector receives transmitted light, 90 ° detector receives scattered light, scattered light and transmitted light intensity ratio is proportional to the turbidity of the sample, you can determine the ratio of the intensity of the scattered light and transmitted light so as to calculate the value of the turbidity of the sample.
Portable turbidimeter combines the scattered light method and transmitted light method, the instrument is set up with 90 ° and 180 ° two detectors, 180 ° detector receives transmitted light, 90 ° detector receives scattered light, scattered light and transmitted light intensity ratio is proportional to the turbidity of the sample, you can determine the ratio of the intensity of the scattered light and transmitted light so as to calculate the value of the turbidity of the sample.
Product features
- Low turbidity detection
- Dual detection
- Red laser light source
- Dual measurement modes
- 3 measurement units
- Three-point calibration
- Log export
- Screen brightness setting
- Lightweight and portable
- IP65 waterproof
Application Areas
- Factory water
- Secondary water supply
- Terminal water
- Swimming pools
Product features
- Low turbidity detection
- Dual detection
- Red laser light source
- Dual measurement modes
- 3 measurement units
- Three-point calibration
- Log export
- Screen brightness setting
- Lightweight and portable
- IP65 waterproof
Application Areas
- Factory water
- Secondary water supply
- Terminal water
- Swimming pools
Technical Parameters
Instrument Specifications | |
Range | 0~20NTU |
Resolution | 0.001/0.01/0.1NTU |
Display Error | ≤±0.05NTU@<1NTU; ≤±5%@≥1NTU: |
Repeatability | ≤0.05NTU@<1NTU; ≤2%@≥1NTU: |
Zero Drift | ≤±0.3%F.S/30 each minute; |
Operating Temperature | 5~40℃ |
Storage Temperature | -10~55℃ |
Humidity | 0~80%RH |
Power supply | Lithium battery (optional dry cell) |
Protection class | IP65 |
Dimension | 170X72X44mm |
Weight | 290g |
Technical Parameters
Instrument Specifications | |
Range | 0~20NTU |
Resolution | 0.001/0.01/0.1NTU |
Display Error | ≤±0.05NTU@<1NTU; ≤±5%@≥1NTU: |
Repeatability | ≤0.05NTU@<1NTU; ≤2%@≥1NTU: |
Zero Drift | ≤±0.3%F.S/30 each minute; |
Operating Temperature | 5~40℃ |
Storage Temperature | -10~55℃ |
Humidity | 0~80%RH |
Power supply | Lithium battery (optional dry cell) |
Protection class | IP65 |
Dimension | 170X72X44mm |
Weight | 290g |