TO MAKE THE WORLD CLOSER TO THE TRUTH
TO MAKE THE WORLD CLOSER TO THE TRUTH
Availability: | |
---|---|
Quantity: | |
T302SI / T302IPro
TOP
Main Features:
The 302nm LED UV transilluminator applied for observe the results of nucleic acid (DNA/RNA) gel electrophoresis and do gel cutting operations. Unique LED light panel provides clearer bands observation. The exquisite structural design can achieve convenient observe, detect and cut the electrophoresis gel. 302nm wavelength can excite the fluorescent dye/DNA complex to produce fluorescence to the greatest extent, with high sensitivity, clear observation bands, strong illumination, and uniform brightness. It is also equipped with special UV filter glass with selective absorption ability for specific wavelengths of UV, effectively ensure excitation sensitivity.
Advantage:
1. Unique built-in bottom LED UV light source, lower power consumption and service life of more than 50,000 hours;
2. LED UV lamp beads make the wavelength is more concentrated and the radiation distance is shorter, which greatly reduce harmfulness to the human body;
3. Bottom UV light source irradiation, no reflected light interference, high observation and imaging quality. Uniform brightness, effectively excite gel sheet and make bands clearer;
4. Adjustable light intensity and contrast according to the different experiment purposes and environment, can achieve the best observation or imaging quality;
5. Superconducting heat dissipation design, no noise during use, providing a comfortable experimental environment;
6. The metal base is more stable, the device thickness is only 30mm, weight is 1300g, lightweight and compact;
7. Automatically shuts down after 5 minutes, which can protect the transilluminator from risks caused by user negligence and improve the safety of use;
8. The UV protection lid can be rotated to 90°, which facilitates observation and gel bands cutting and provides maximum UV protection without affecting observation;
9. There is a convenient darkroom for taking bands pictures, which can be taken and uploaded instantly with a mobile phone, and a special gel-cutting tool is also included;
10. Different observation areas are available: 150*120mm/200*130mm;
11. Applied forEtBr,SYBR Safe,SYBR Gold,SYBR Green l/ll,SYPRO Ruby, SYPRO Orange, SYPRO Red, Coomassie Fluorrm Orange stains,GelRed, Redsafe etc.excitation and recovery of nucleic acid and protein geldyes.
Main Features:
The 302nm LED UV transilluminator applied for observe the results of nucleic acid (DNA/RNA) gel electrophoresis and do gel cutting operations. Unique LED light panel provides clearer bands observation. The exquisite structural design can achieve convenient observe, detect and cut the electrophoresis gel. 302nm wavelength can excite the fluorescent dye/DNA complex to produce fluorescence to the greatest extent, with high sensitivity, clear observation bands, strong illumination, and uniform brightness. It is also equipped with special UV filter glass with selective absorption ability for specific wavelengths of UV, effectively ensure excitation sensitivity.
Advantage:
1. Unique built-in bottom LED UV light source, lower power consumption and service life of more than 50,000 hours;
2. LED UV lamp beads make the wavelength is more concentrated and the radiation distance is shorter, which greatly reduce harmfulness to the human body;
3. Bottom UV light source irradiation, no reflected light interference, high observation and imaging quality. Uniform brightness, effectively excite gel sheet and make bands clearer;
4. Adjustable light intensity and contrast according to the different experiment purposes and environment, can achieve the best observation or imaging quality;
5. Superconducting heat dissipation design, no noise during use, providing a comfortable experimental environment;
6. The metal base is more stable, the device thickness is only 30mm, weight is 1300g, lightweight and compact;
7. Automatically shuts down after 5 minutes, which can protect the transilluminator from risks caused by user negligence and improve the safety of use;
8. The UV protection lid can be rotated to 90°, which facilitates observation and gel bands cutting and provides maximum UV protection without affecting observation;
9. There is a convenient darkroom for taking bands pictures, which can be taken and uploaded instantly with a mobile phone, and a special gel-cutting tool is also included;
10. Different observation areas are available: 150*120mm/200*130mm;
11. Applied forEtBr,SYBR Safe,SYBR Gold,SYBR Green l/ll,SYPRO Ruby, SYPRO Orange, SYPRO Red, Coomassie Fluorrm Orange stains,GelRed, Redsafe etc.excitation and recovery of nucleic acid and protein geldyes.
Machine parameters:
Model | T302SI | T302IPro |
Observation area | L150×W120mm | L200×W130mm |
Power | 12V 1A | |
LED source | UV LED light | |
LED lifetime | >50,000h | |
Emission wavelength | 302nm | |
Auto shutdown time | 5min | |
Dimension | L260×W192×H30mm | |
Weight | 1.3kg | |
Voltage/Frequency | 100~240V;50/60Hz |
Machine parameters:
Model | T302SI | T302IPro |
Observation area | L150×W120mm | L200×W130mm |
Power | 12V 1A | |
LED source | UV LED light | |
LED lifetime | >50,000h | |
Emission wavelength | 302nm | |
Auto shutdown time | 5min | |
Dimension | L260×W192×H30mm | |
Weight | 1.3kg | |
Voltage/Frequency | 100~240V;50/60Hz |