Availability: | |
---|---|
Quantity: | |
PUL-5000/5000F
TOP
Ultra micro UV visible spectrophotometer is an important analytical instrument, which has wide and important applications in scientific research fields such as physics, chemistry, biology, medicine, materials science, environmental science, as well as in modern production and management departments such as chemical engineering, medicine, environmental testing, metallurgy, etc. The spectrophotometer is an instrument that uses spectrophotometry to quantitatively and qualitatively analyze substances, and has become a routine instrument in modern molecular biology laboratories. Commonly used for nucleic acid, protein quantification, and bacterial growth concentration quantification.
Detect the required trace amount of sample, with a minimum requirement of only 0.3ul, using both ultra trace and colorimetric dual platforms
Wide detection range, 500 times higher than the upper limit of traditional spectrophotometers
For most samples, no dilution is required
The machine does not require preheating, can measure directly, does not require container inspection, and has low daily consumption
Full wavelength range of 190-1100nm with a resolution of 1nm. The instrument automatically provides scanning results for the full wavelength range of 190-900nm
Compact size, portable packaging, meeting the needs of on-site testing
Realize more accurate and flexible measurements through PC control
Ultra micro UV visible spectrophotometer is an important analytical instrument, which has wide and important applications in scientific research fields such as physics, chemistry, biology, medicine, materials science, environmental science, as well as in modern production and management departments such as chemical engineering, medicine, environmental testing, metallurgy, etc. The spectrophotometer is an instrument that uses spectrophotometry to quantitatively and qualitatively analyze substances, and has become a routine instrument in modern molecular biology laboratories. Commonly used for nucleic acid, protein quantification, and bacterial growth concentration quantification.
Detect the required trace amount of sample, with a minimum requirement of only 0.3ul, using both ultra trace and colorimetric dual platforms
Wide detection range, 500 times higher than the upper limit of traditional spectrophotometers
For most samples, no dilution is required
The machine does not require preheating, can measure directly, does not require container inspection, and has low daily consumption
Full wavelength range of 190-1100nm with a resolution of 1nm. The instrument automatically provides scanning results for the full wavelength range of 190-900nm
Compact size, portable packaging, meeting the needs of on-site testing
Realize more accurate and flexible measurements through PC control
Host | PUL-5000/5000F |
Minimum sample size | 0.3μl |
Ultramicropath | Continuous optical path of 0.02 to 1mm, with automatic switching |
Wavelength coverage | 190~900nm |
Wavelength accuracy | 1nm |
Wavelength resolution | 1nm |
Absorbance accuracy | ±1%(0.76在260nm) |
Absorbance resolution accuracy | 0.002Abs (1mm optical path) |
Light absorption range | 0-750A (equivalent 10mm optical path length) |
OD600 absorbance range | 0~4.000Abs |
OD600 absorbance stability | [0,3)≤0.5%,[3,4)≤2% |
OD600 absorbance repeatability | [0,3)≤0.5%,[3,4)≤2% |
Fluorescence detection linearity | R2>0.996(UL-5000F) |
Scope of nucleic acid testing | 1.5~37500 ng/ul (dSDNA), detection limit of 1.5 ng/ul |
Protein detection range | 0.05~1110 mg/ml(BSA),0.03~540 mg/ml(lgG) |
Detector | UV enhanced CMOS line array sensor |
Light source | Imported miniature xenon flash system, flashes 109 times, with a lifespan of up to 10 years |
Measure Time | <3 s |
LCD screen | 7-inch touch operation screen, Android system |
Characteristic | Adopting the principle of fixed optical path length, there is no need for calibration for life. Samples of 304 stainless steel and quartz that can detect volatile solvents |
Sample detection platform material | 304 stainless steel and quartz |
Host | PUL-5000/5000F |
Minimum sample size | 0.3μl |
Ultramicropath | Continuous optical path of 0.02 to 1mm, with automatic switching |
Wavelength coverage | 190~900nm |
Wavelength accuracy | 1nm |
Wavelength resolution | 1nm |
Absorbance accuracy | ±1%(0.76在260nm) |
Absorbance resolution accuracy | 0.002Abs (1mm optical path) |
Light absorption range | 0-750A (equivalent 10mm optical path length) |
OD600 absorbance range | 0~4.000Abs |
OD600 absorbance stability | [0,3)≤0.5%,[3,4)≤2% |
OD600 absorbance repeatability | [0,3)≤0.5%,[3,4)≤2% |
Fluorescence detection linearity | R2>0.996(UL-5000F) |
Scope of nucleic acid testing | 1.5~37500 ng/ul (dSDNA), detection limit of 1.5 ng/ul |
Protein detection range | 0.05~1110 mg/ml(BSA),0.03~540 mg/ml(lgG) |
Detector | UV enhanced CMOS line array sensor |
Light source | Imported miniature xenon flash system, flashes 109 times, with a lifespan of up to 10 years |
Measure Time | <3 s |
LCD screen | 7-inch touch operation screen, Android system |
Characteristic | Adopting the principle of fixed optical path length, there is no need for calibration for life. Samples of 304 stainless steel and quartz that can detect volatile solvents |
Sample detection platform material | 304 stainless steel and quartz |