PAA-1800 Series Atomic Absorption Spectrometer with Graphite Furnace & Fully Automated Optical System

Wavelength range: 190–900 nm with automatic peak search and optical optimization
Wavelength accuracy: ≤0.15 nm; Repeatability: ±0.1 nm
Spectral bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0 nm (auto selectable)
Detection limit: 0.002 μg/mL (Cu)
Precision (RSD): ≤0.5%
Graphite furnace temperature control: up to 3000 ℃, fully automatic with 20 programmable steps
Sample capacity (optional autosampler): 130 samples with injection volume range 0.01–100 μL
 
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • PAA-1800 series

  • TOP

  • PAA-1800 series products adopt a double-layer cast aluminum plate structure, which is not easily deformed after long-term high temperature use and has good heat dissipation; The graphite furnace method for light controlled heating can directly monitor the temperature of the inner wall of the graphite tube: the step precision 0.005nm wavelength precision screw drive increases the accuracy and repeatability of the instrument wavelength; Deuterium hollow cathode lamp buckle background, long service life. Abnormal automatic alarm, automatic system shutdown, and automatic power-off can save measurement data.


  • High precision fully automated optical system

  • A large-area grating with a dispersion rate of 1800 lines per millimeter, a new self collimating monochromator, and all lenses are coated with quartz. The wide detection range and optical stability ensure the accuracy of analysis. The fully automatic 6-lamp holder is equipped with six independent lamp power supplies, which can be preheated separately.

  • Polymer Atomization Laboratory

  • Polymer material corrosion-resistant atomization chamber, acid and alkali resistant, including hydrofluoric acid, can achieve good sensitivity and stability in both organic and inorganic solutions.

  • Titanium burner

  • Optional 50mm and 100mm burners, air-cooled premixed type, corrosion-resistant, high salt resistant, greatly improving flame efficiency and flame analysis accuracy

  • Fully automated analysis

  • It can automatically complete safe ignition, extinguishing, and switching, with a reliable structure and low failure rate, thus ensuring the sensitivity and reproducibility of the flame method. The lamp position platform automatically switches, and high-performance hollow cathode lamps can be directly used to improve the sensitivity of flame analysis. The power supply parameters and beam position are automatically adjusted, and the wavelength scanning and peak finding are fully automatic

  • High tech indicators

  • The element testing sensitivity of PAA-1800 atomic absorption spectrometer has reached the advanced level in the industry, with a sensitivity of ≤ 0.015ug/mL/1%; Baseline drift less than 0.003Abs/30m, stability better than 0.005Abs/4h

  • Background correction system

  • The use of tritium hollow cathode lamp and self absorbing buckle background for background correction eliminates the interference of molecular absorption during low content determination, reduces the emission noise of the lamp, prolongs its service life, and has good stability. When the background signal of the deuterium lamp is 1A, the background subtraction ability is greater than 50 times

  • Intelligent analysis

  • Very intelligent, user-friendly design, automatic setting and adjustment of flame height, automatic ignition, automatic optimization of horizontal position, and system automatic setting of gas flow rate. In case of power outage, misoperation, acetylene leakage, etc., the system will automatically activate the safety protection function


Host

PAA-1800F

PAA-1800C

PAA-1800D

Light source

Three lamp platform switching, fully automatic collimation


Six light automatic switching, fully automatic collimation

Automatic switching of eight lights, fully automatic collimation

Wavelength coverage

190-900nm, automatic peak search, one click optical optimization function

Wavelength accuracy

≤0.15nm

Wavelength Repeatability

±0.1nm

Spectral bandwidth

0.1, 0.2, 0.4, 1.0, and 2.0nm Automatic settings


Host

PAA-1800S

PAA-1800H

PAA-1800E

Light source

Six lamp platform switching, fully automatic collimation

Six light automatic switching, fully automatic collimation

Automatic switching of eight lights, fully automatic collimation

Wavelength coverage

190-900nm, automatic peak search, one click optical optimization function

Wavelength accuracy

≤0.15nm

Wavelength Repeatability

±0.1nm

Spectral bandwidth

0.1, 0.2, 0.4, 1.0, and 2.0nm Automatic settings

Lamp base

Single element or multi-element hollow cathode lamp

Lamp current

Pulse power supply

Optical system

Large area 1800/mm engraved line grating, fully enclosed optical system

Baseline drift

Static ≤±0.002A/30 minutes, dynamic ≤±0.005A/30 minutes

Range of absorbance

0-4A

Detector

Imported photomultiplier tube

Flame system


Combustion head

All titanium combustion head, 50mm or 100mm universal combustion head polymer explosion-proof and anti-corrosion atomization chamber

Atomization chamber

Efficient glass atomizer, also customizable

Atomizer

Microcomputer control, automatic ignition

Ignition method

Fully automatic gas control system

Gas control

0.015ug/mL/1%(Cu)

Characteristic Concentration

0.002μg/mL(Cu)

Detection limit

RSD≤0.5%

Precision

Multiple protective measures such as gas leakage alarm, automatic protection against backfire, and automatic power-off in case of abnormalities

Safety

All titanium combustion head, 50mm or 100mm universal combustion head polymer explosion-proof and anti-corrosion atomization chamber

Graphite furnace system


Heating method

Longitudinal heating

Temperature control

Longitudinal optical temperature control monitoring of graphite tube inner wall temperature

Temperature range

Room temperature to 3000 ℃

Program temperature control

Fully automatic temperature control up to 20 levels, enrichment and concentration in the furnace up to 20 times

Feature

0.5x10-12g(Cd)

Detection limit

0.4x10-12g(Cd)

Precision

RSD≤3%

Cooling water

Optional cooling water circulation system

Safety

Alarm for graphite tube damage, water flow rate, air pressure, etc; Overheating protection for water temperature

Graphite furnace automatic sampler (optional)


Sample tray

130 sample cups, 6 reagent cups

Injection volume

0.01-100 μl,

Minimum increment

0.01 μl,

Sample volume repeatability

1%

Repeated injection times

Up to 99 times

Cleaning container capacity

500mL

Data processing


Measurement method

Flame method, graphite furnace method, hydride atomic absorption method

Concentration calculation method

Standard curve method (1-3 degree curve), automatic fitting, standard addition method

Repeated measurement times

1-99 times, calculate the average, provide the standard deviation and relative standard deviation

Result printing

Parameter printing, data result printing, graphic printing, can export WORD and EXCEL documents


Previous: 
Next: 
To Make The World Closer To The Truth
ZHEJIANG TOP INSTRUMENT CO.,LTD., as a subsidiary of TOP Cloud agri, is a high-tech enterprise specializing in the R&D, manufacturing, sales for laboratory equipments, and provision of comprehensive laboratory solutions.

CONTACT US

  +86-571-86062776
 +86-571-86059660
   11-12th Floor, 3rd Building, Xiangyuan Rd. China (Hangzhou) Wisdom Information Industry Park, Hangzhou, P.R.C 310015
Copyright   2023 Zhejiang Top Instrument Co., Ltd. Support by Leadong. Sitemap.Privacy Policy