Availability: | |
---|---|
Quantity: | |
PA series
TOP
I、 Application areas:
Suitable for daily laboratory primary pure water and analytical pure water, it can completely replace traditional distilled water dispensers, meet the requirements of the vast majority of chemical and biological experimental water, conventional production process water, and laboratory vessel cleaning water, and can be used as a water supply source for ultrapure water systems, high-pressure steam sterilizers, environmental testing chambers, and other instruments.
II、 Performance characteristics:
1. Fully automatic microcomputer control system, LED LCD screen displays real-time animated working status throughout the process.
2. The operating status is clear and intuitive, with real-time display of flushing, water production, full water, short water, and maintenance status.
3. It has functions such as power on self-test, power-off reset, low and high voltage protection sound and light alarm.
4. It has startup, water shortage reset, and cumulative water production and flushing programs. Maximum program extension of RO membrane lifespan.
5. Adopting high-end engineering plastic chassis, sturdy and durable, beautiful and elegant, ergonomic design, and water electricity separation structure.
6. Unique consumable design, using quick plug interface for easy installation and replacement, with pure water pipelines and joints certified by NSF.
7. The main power supply is low voltage 24VDC, which complies with safety regulations and can be used in humid environments without causing harm to personnel. Adopting advanced electromagnetic compatibility design, it has strong anti-interference ability and low noise.
8. After selecting a pressure water tank or a liquid level water tank, it can achieve fully automatic operation in conjunction with laboratory instruments.
I、 Application areas:
Suitable for daily laboratory primary pure water and analytical pure water, it can completely replace traditional distilled water dispensers, meet the requirements of the vast majority of chemical and biological experimental water, conventional production process water, and laboratory vessel cleaning water, and can be used as a water supply source for ultrapure water systems, high-pressure steam sterilizers, environmental testing chambers, and other instruments.
II、 Performance characteristics:
1. Fully automatic microcomputer control system, LED LCD screen displays real-time animated working status throughout the process.
2. The operating status is clear and intuitive, with real-time display of flushing, water production, full water, short water, and maintenance status.
3. It has functions such as power on self-test, power-off reset, low and high voltage protection sound and light alarm.
4. It has startup, water shortage reset, and cumulative water production and flushing programs. Maximum program extension of RO membrane lifespan.
5. Adopting high-end engineering plastic chassis, sturdy and durable, beautiful and elegant, ergonomic design, and water electricity separation structure.
6. Unique consumable design, using quick plug interface for easy installation and replacement, with pure water pipelines and joints certified by NSF.
7. The main power supply is low voltage 24VDC, which complies with safety regulations and can be used in humid environments without causing harm to personnel. Adopting advanced electromagnetic compatibility design, it has strong anti-interference ability and low noise.
8. After selecting a pressure water tank or a liquid level water tank, it can achieve fully automatic operation in conjunction with laboratory instruments.
Product model | PA-10B/20B/30B/40B |
Water production capacity | 10L/H;20L/H,30L/H,40L/H |
Inlet requirements | urban tap water: TDS < 300ppm, 5-45 ℃, 1.0-4.0kgf/cm ² |
Instant water intake | 1.5-2.0L/min (when the water tank is full) |
DI deionized water index | |
Electrical resistivity | 10-16.5MΩ.CM@25℃ |
Heavy metal ions | <0.1ppb |
Particulate matter (>0.2 μ m) | <1/ml |
RO reverse osmosis pure water index | |
Conductivity | <source water conductivity x 2% |
Ion retention rate | ≥ 96% -98% (using new RO membrane) |
Particle and bacterial retention rate | ≥98% |
Water outlets | 2 outlets: reverse osmosis water, deionized water |
Dimensions | Length * Width * Height: 365 * 400 * 450mm |
Weight | 16-19kg |
Power supply | 220V,50/60Hz |
Power | 45-100W |
System configuration | host (including complete set of consumables+pressure water tank)+accessory package |
Product model | PA-10B/20B/30B/40B |
Water production capacity | 10L/H;20L/H,30L/H,40L/H |
Inlet requirements | urban tap water: TDS < 300ppm, 5-45 ℃, 1.0-4.0kgf/cm ² |
Instant water intake | 1.5-2.0L/min (when the water tank is full) |
DI deionized water index | |
Electrical resistivity | 10-16.5MΩ.CM@25℃ |
Heavy metal ions | <0.1ppb |
Particulate matter (>0.2 μ m) | <1/ml |
RO reverse osmosis pure water index | |
Conductivity | <source water conductivity x 2% |
Ion retention rate | ≥ 96% -98% (using new RO membrane) |
Particle and bacterial retention rate | ≥98% |
Water outlets | 2 outlets: reverse osmosis water, deionized water |
Dimensions | Length * Width * Height: 365 * 400 * 450mm |
Weight | 16-19kg |
Power supply | 220V,50/60Hz |
Power | 45-100W |
System configuration | host (including complete set of consumables+pressure water tank)+accessory package |