Feature:
Applicable to various water quality, the case is with powder coating.
The filter element adopts open mold injection technology and inside the machine
Korean quick-insert filter column is easy to replace and maintain.
The electrical appliance and waterways are completely separated to avoid circuit
failure caused by moisture and water leakage.
Online water quality monitoring system, immediately measure the output water quality.
Automatic RO membrane anti-scaling flushing program, automatic stop when tap water break, automatic water breaking when machine stop, storage tank automatically fill water, automatic stopping when water is full.
NSF certified pipeline has function of upgrading water quality and quantity.
Equipped with a portable TDS pen, you can test TDS content, conductance, water temperature anytime, anywhere.
Double electric water intakes, two kinds water quality, ready to use. Pressure online monitoring.
Open door at front and back, this make filters replacement easy&convenient, the replacement can be easily completed without using any tools.
Double water intakes: RO water and UP water
Feature:
Applicable to various water quality, the case is with powder coating.
The filter element adopts open mold injection technology and inside the machine
Korean quick-insert filter column is easy to replace and maintain.
The electrical appliance and waterways are completely separated to avoid circuit
failure caused by moisture and water leakage.
Online water quality monitoring system, immediately measure the output water quality.
Automatic RO membrane anti-scaling flushing program, automatic stop when tap water break, automatic water breaking when machine stop, storage tank automatically fill water, automatic stopping when water is full.
NSF certified pipeline has function of upgrading water quality and quantity.
Equipped with a portable TDS pen, you can test TDS content, conductance, water temperature anytime, anywhere.
Double electric water intakes, two kinds water quality, ready to use. Pressure online monitoring.
Open door at front and back, this make filters replacement easy&convenient, the replacement can be easily completed without using any tools.
Double water intakes: RO water and UP water
P-UPW series ultrapure water machine | ||||
Type classification | Standard | Low Endotoxin | Low TOC | Comprehensive |
The machine model | P-UPW | P-UPW-F | P-UPW-V | P-UPW-VF |
Water rate | 10/20/30 lph | |||
The water requirements | Urban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃ | |||
RO water Parameter | ||||
Ion rejection rate | 97%-99% (when using a new RO membrane) | |||
Organic matter rejection rate | >99% when MW>200 Dalton | |||
Particle and bacterial rejection | > 99% | |||
UP water Parameter(ASTM TYPE I grade water) | ||||
Resistivity (25℃) | 18.25 M Ω. Cm @ 25 ℃ | |||
Heavy metal ion | < 0.01 ppb | |||
Total organic carbon (TOC) * | <10 ppb | <3 ppb | ||
bacteria | < 1 cfu/ml *(with terminal filter) | |||
Particulate matter (> 0.1 microns) | <1/ml | |||
Pyrogen (endotoxin) | N/A | < 0.001 Eu/ml | N/A | < 0.001 Eu/ml |
Ribonuclease (RNases) | N/A | <1pg/ml | N/A | <1pg/ml |
Deoxyribonucleases | N/A | <5pg/ml | N/A | <5pg/ml |
Application | All kinds of physical and chemical testing, biochemical analysis, blood examination, microanalysis, flushing special, HPLC, IC, GC, analysis experiment | High sensitivity ICP/MS, PCR, PPT level analysis, isotope analysis, molecular biology, life science, CDC, drug control institute, quality inspection institute | Atomic absorption/emission spectrometry, mass spectrometry, TOC detection, environmental monitoring, biochip development, trace organic matter analysis | Molecular biology, Life sciences, gene research, cell culture, amino acid analysis, protein purification, toxicology, drug development, medical testing |
Electrical requirements | 100-240V, 50/60Hz, 48-72W | |||
The system configuration | Host machine (including 1 set of purification column)+12L pressure water storage tank +TDS pen + accessory bag |
P-UPW series ultrapure water machine | ||||
Type classification | Standard | Low Endotoxin | Low TOC | Comprehensive |
The machine model | P-UPW | P-UPW-F | P-UPW-V | P-UPW-VF |
Water rate | 10/20/30 lph | |||
The water requirements | Urban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃ | |||
RO water Parameter | ||||
Ion rejection rate | 97%-99% (when using a new RO membrane) | |||
Organic matter rejection rate | >99% when MW>200 Dalton | |||
Particle and bacterial rejection | > 99% | |||
UP water Parameter(ASTM TYPE I grade water) | ||||
Resistivity (25℃) | 18.25 M Ω. Cm @ 25 ℃ | |||
Heavy metal ion | < 0.01 ppb | |||
Total organic carbon (TOC) * | <10 ppb | <3 ppb | ||
bacteria | < 1 cfu/ml *(with terminal filter) | |||
Particulate matter (> 0.1 microns) | <1/ml | |||
Pyrogen (endotoxin) | N/A | < 0.001 Eu/ml | N/A | < 0.001 Eu/ml |
Ribonuclease (RNases) | N/A | <1pg/ml | N/A | <1pg/ml |
Deoxyribonucleases | N/A | <5pg/ml | N/A | <5pg/ml |
Application | All kinds of physical and chemical testing, biochemical analysis, blood examination, microanalysis, flushing special, HPLC, IC, GC, analysis experiment | High sensitivity ICP/MS, PCR, PPT level analysis, isotope analysis, molecular biology, life science, CDC, drug control institute, quality inspection institute | Atomic absorption/emission spectrometry, mass spectrometry, TOC detection, environmental monitoring, biochip development, trace organic matter analysis | Molecular biology, Life sciences, gene research, cell culture, amino acid analysis, protein purification, toxicology, drug development, medical testing |
Electrical requirements | 100-240V, 50/60Hz, 48-72W | |||
The system configuration | Host machine (including 1 set of purification column)+12L pressure water storage tank +TDS pen + accessory bag |