Availability: | |
---|---|
Quantity: | |
TS-1096A
TOP
Main Features:
◇ Industrial grade color LCD display, touch screen operation.
◇ Eight channel optical fiber measurement system, imported detector.
◇ Center positioning function, accurate and reliable.
◇ Three kinds of linear vibration plate function.
◇ Unique open Cut-Off judgment formula.
◇ End point method, two point method, dynamics, single / dual wavelength test mode.
◇ Configure the inhibition rate measurement module, dedicated to the field of food safety medical testing and ect.
Main Features:
◇ Industrial grade color LCD display, touch screen operation.
◇ Eight channel optical fiber measurement system, imported detector.
◇ Center positioning function, accurate and reliable.
◇ Three kinds of linear vibration plate function.
◇ Unique open Cut-Off judgment formula.
◇ End point method, two point method, dynamics, single / dual wavelength test mode.
◇ Configure the inhibition rate measurement module, dedicated to the field of food safety medical testing and ect.
Machine parameters:
Lamp | DC12V 22W Tungsten halogen lamp |
Optical path | 8 channel vertical light path system |
Wavelength range | 400-1000nm(Selection 340-1100nm) |
Filter | Default configuration 405、450、492、630nm, Can be installed up to 15 filters. |
Reading range | 0-4.000Abs |
Linear range | 0-3.000Abs |
Resolution | 0.001Abs |
Accuracy | ≤±0.01Abs |
Stability | ≤±0.003Abs |
Repeatability | ≤0.3% |
Incubation function | room temperature+4℃~50℃,accuracy 37℃±0.5℃(Selection) |
Vibration plate | Three kinds of linear vibration plate function, Adjustable 0-255 seconds |
Display | 8 inch color LCD screen, display the entire board information, touch screen operation. |
Software | Professional software, Can store 200 groups program, 100000 sample results,More than10 kinds of curve fitting equation. |
Power input | AC100-240V 50-60Hz |
Weight | 11Kg |
Size | 433mm(L)*320mm(W)*308mm(H) |
Machine parameters:
Lamp | DC12V 22W Tungsten halogen lamp |
Optical path | 8 channel vertical light path system |
Wavelength range | 400-1000nm(Selection 340-1100nm) |
Filter | Default configuration 405、450、492、630nm, Can be installed up to 15 filters. |
Reading range | 0-4.000Abs |
Linear range | 0-3.000Abs |
Resolution | 0.001Abs |
Accuracy | ≤±0.01Abs |
Stability | ≤±0.003Abs |
Repeatability | ≤0.3% |
Incubation function | room temperature+4℃~50℃,accuracy 37℃±0.5℃(Selection) |
Vibration plate | Three kinds of linear vibration plate function, Adjustable 0-255 seconds |
Display | 8 inch color LCD screen, display the entire board information, touch screen operation. |
Software | Professional software, Can store 200 groups program, 100000 sample results,More than10 kinds of curve fitting equation. |
Power input | AC100-240V 50-60Hz |
Weight | 11Kg |
Size | 433mm(L)*320mm(W)*308mm(H) |