TO MAKE THE WORLD CLOSER TO THE TRUTH

PZF-06/PZF-06A Fully Automatic Organic Solvent Extractor with Touch Screen, Multi-Program Control, and Solvent Recovery
You are here: home » Products » Chemical Analysis Instruments » Fat Analyzers » PZF-06/PZF-06A Fully Automatic Organic Solvent Extractor with Touch Screen, Multi-Program Control, and Solvent Recovery

Product Category

loading

PZF-06/PZF-06A Fully Automatic Organic Solvent Extractor with Touch Screen, Multi-Program Control, and Solvent Recovery

Fully automatic organic solvent extractor with 7-inch color touch screen and intuitive menu-based program editing
Supports up to 40 program segments, multi-temperature, multi-level or cyclic soaking, extraction, reflux, and valve control
Recipe management stores up to 99 analysis programs, automatic lifting and pressing system for consistent sample immersion
Integral metal bath heating block with wide temperature range RT+5℃ to 300℃, high temperature control accuracy ±1℃
Two solvent cups (aluminum alloy and glass) with solvent recovery rate ≥85%, electromagnetic automatic solvent return
Electronic refrigeration cycle cooling system built-in (PZF-06A), energy-saving and environmentally friendly
Determines 6 samples per run, sample weight 0.5–15g
 
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • PZF-06 / PZF-06A

  • TOP

Characteristic:

  • ★ One-Button Automatic Operation: Automatically completes the entire process, including solvent cup clamping, sample basket lifting/lowering, heating, soaking, extraction, reflux, solvent recovery, and valve opening/closing.

  • ★ Flexible Extraction Modes: Room-temperature soaking, hot soaking, hot extraction, continuous extraction, intermittent extraction, and solvent recovery can be selected and combined freely.

  • ★ Multiple Solenoid Valve Control Modes: Supports jog control, timed opening/closing, and manual operation.

  • Recipe Management: Stores up to 99 different analysis programs for convenient management and reuse.

  • Automatic Lifting and Clamping System: Highly automated, reliable, and easy to operate.

  • 7-Inch Color Touchscreen: Features a user-friendly interface for intuitive and easy operation.

  • Menu-Based Program Editing: Intuitive and easy to use, with support for repeated cycle operations.

  • Up to 40 Program Segments: Supports multi-temperature, multi-stage, and repeated or cyclic soaking, extraction, and heating processes.

  • Integrated Metal Heating Block: Provides a wide temperature range and high-precision temperature control.

  • Automatic Filter Cup Holder Lifting: Ensures all samples are immersed in the organic solvent simultaneously, helping improve the consistency of measurement results.

  • Solvent Compatibility: Professionally customized components are suitable for various organic solvents, including petroleum ether, ether, alcohols, and other selected organic solvents.

  • Petroleum Ether Leakage Alarm: When petroleum ether leakage reaches a potentially hazardous level, the alarm system is activated and heating is automatically stopped.

  • Two Solvent Cup Options: Available with aluminum alloy or glass solvent cups, allowing users to choose according to their application needs.


Only PZF-06A

  • ★ Patented “Built-In Electronic Cooling System”
    The built-in electronic cooling system eliminates the need for an external water source, significantly reduces tap water consumption, and uses no chemical refrigerants. It is energy-efficient, environmentally friendly, and provides high-efficiency extraction and reflux.

  • ★ Patented “Automatic Organic Solvent Addition System”
    A. Built-in diaphragm organic solvent pump automatically adds organic solvents in a sealed environment, eliminating the need for manual operation.
    B. Automatic solvent addition volume: 5–150 mL. Solvent can be added sequentially to all 6 solvent cups or to a designated solvent cup.
    C. Solvent can be automatically added by the programmed procedure at any stage of the analysis.

  • ★ Automatic Organic Solvent Collection System
    A. The built-in diaphragm organic solvent pump automatically recovers the organic solvent.
    B. After the extraction program is completed, the instrument automatically transfers the recovered solvent into the dedicated sealed solvent container for reuse.

  • Fully Automatic Operation Without Manual Intervention
    The entire process is completed automatically:
    Automatic solvent addition → Complete extraction process → Automatic solvent replenishment during extraction → Sample cup pre-drying → Automatic solvent recovery into the external solvent container.




SpecificationPZF-06APZF-06
Measurement Range0–100%0.1–100%
Temperature Control RangeRT + 5°C to 300°CRT + 5°C to 300°C
Temperature Control Accuracy±1°C±1°C
Sample Capacity6 samples/batch6 samples/batch
Sample Weight0.5–15 g0.5–15 g
Solvent Cup Volume150 mL150 mL
Solvent Recovery Rate≥80%≥85%
Control Screen—7-inch
Automatic Solvent Addition≤100 mL—
Solvent Addition ModesAutomatic addition; automatic addition during operation without stopping; manual addition—
Solvent CollectionAutomatically recovered into the solvent container after operation—
Stainless Steel Solvent Container1.5 L—
Solvent Reflux Plug—Automatic electromagnetic opening/closing
Extraction Unit Lifting System—Automatic lifting/lowering
Heating Power1.8 kW1.5 kW
Electronic Cooling Power1 kW—
Working VoltageAC 220 V / 50–60 Hz220 V ±10% / 50 Hz



Previous: 
Next: 

Related Products

content is empty!

To Make The World Closer To The Truth
ZHEJIANG TOP INSTRUMENT CO.,LTD., as a subsidiary of TOP Cloud agri, is a high-tech enterprise specializing in the R&D, manufacturing, sales for laboratory equipments, and provision of comprehensive laboratory solutions.

CONTACT US

  +86-571-86062776
 +86-571-86059660
  No 182, Xiju Road, Shangtang street, Hangzhou City, PRC
Copyright   2023 Zhejiang Top Instrument Co., Ltd. Support by Leadong. Sitemap.Privacy Policy