Characteristic:
Four ranges, automatic switching, automatic carry display, simple operation, high measurement accuracy.
The temperature is automatically measured and displayed, and the solution is automatically temperature compensated.
It adopts 3-digit LCD digital display, the temperature and measured value are displayed at the same time, the appearance is beautiful, and the display is clear. The instrument is equipped with a multi-functional electrode bracket to make the operation more convenient.
Four kinds of electrode constants (0.01, 0.1, 1.0, 10) can be selected, which can not only measure the conductivity of general aqueous solution, but also measure the conductivity of high pure water.
With conductivity and TDS conversion function.
Characteristic:
Four ranges, automatic switching, automatic carry display, simple operation, high measurement accuracy.
The temperature is automatically measured and displayed, and the solution is automatically temperature compensated.
It adopts 3-digit LCD digital display, the temperature and measured value are displayed at the same time, the appearance is beautiful, and the display is clear. The instrument is equipped with a multi-functional electrode bracket to make the operation more convenient.
Four kinds of electrode constants (0.01, 0.1, 1.0, 10) can be selected, which can not only measure the conductivity of general aqueous solution, but also measure the conductivity of high pure water.
With conductivity and TDS conversion function.
Measuring range (0~2*105μS•cm-1) | 0.00~19.99μS/cm | 20.0~199.9μS/cm | 200~1999μS/cm | 2.00~20.0mS/cm |
TDS measurement range (0-10.0)g/L | 0.000-19.99 mg/L | 20.0-199.9 mg/L | 200-1999 mg/L | 2000-10.0 g/l |
Electronic unit basic error | ±1.0%(FS) ±l word | |||
Basic error of the instrument | 1.5%(FS)±1 word | |||
Electronic unit temperature compensation error | ±1.0%(FS) ± l word | |||
Temperature Compensation Range ——(5~50)℃, reference temperature 25℃ | ||||
Temperature display range | 0~100℃ | |||
Medium temperature | 5~50℃ | |||
Matching electrodes | DJS-1T plastic electrode, Electrode constant: 1.0 cm-1 | |||
Dimensions (1*b*h) | 240*180*70mm | |||
Weight | 1kg | |||
Normal use conditions | ||||
a) Ambient temperature | (5~50)℃ | |||
b) Relative humidity | Not more than 85% | |||
c) Power supply | DC9V 400mA (inner positive and outer negative) | |||
d) No noticeable vibration | ||||
e) No external magnetic field interference except the earth's magnetic field |
Measuring range (0~2*105μS•cm-1) | 0.00~19.99μS/cm | 20.0~199.9μS/cm | 200~1999μS/cm | 2.00~20.0mS/cm |
TDS measurement range (0-10.0)g/L | 0.000-19.99 mg/L | 20.0-199.9 mg/L | 200-1999 mg/L | 2000-10.0 g/l |
Electronic unit basic error | ±1.0%(FS) ±l word | |||
Basic error of the instrument | 1.5%(FS)±1 word | |||
Electronic unit temperature compensation error | ±1.0%(FS) ± l word | |||
Temperature Compensation Range ——(5~50)℃, reference temperature 25℃ | ||||
Temperature display range | 0~100℃ | |||
Medium temperature | 5~50℃ | |||
Matching electrodes | DJS-1T plastic electrode, Electrode constant: 1.0 cm-1 | |||
Dimensions (1*b*h) | 240*180*70mm | |||
Weight | 1kg | |||
Normal use conditions | ||||
a) Ambient temperature | (5~50)℃ | |||
b) Relative humidity | Not more than 85% | |||
c) Power supply | DC9V 400mA (inner positive and outer negative) | |||
d) No noticeable vibration | ||||
e) No external magnetic field interference except the earth's magnetic field |